Color & Comfort Color & Comfort

Cell Clogging

Cell Clogging

Cell Clogging

Air drafts are blowing on cylinder

Eliminate air drafts

Doctor Blade wipe is improper

Check and reset doctor blade setting

Ink is drying too fast

Add slower drying solvent

Ink resolubility is poor

Use active solvent or reformulate ink

Ink viscosity is too high

Reduce ink viscosity

Press Speed is too fast

Decrease Press Speed

Print impression is excessive

Reset for lighter impressions